Grieser, Jochen ; Lens, Dieter Etienne Mia ; Hartel, Uta ; Klingbeil, Harald ; Laier, Ulrich ; Ningel, Klaus-Peter ; Schäfer, S. ; Zipfel, Bernhard (2022)
A digital beam-phase control system for a heavy-ion synchrotron with a double-harmonic cavity system.
IPAC2013: the 4th International Particle Accelerator Conference. Shanghai, China (12.05.2013-17.05.2013)
doi: 10.26083/tuprints-00020328
Conference or Workshop Item, Secondary publication, Publisher's Version
Text
wepme004.pdf Copyright Information: CC BY 3.0 Unported - Creative Commons, Attribution. Download (437kB) |
Item Type: | Conference or Workshop Item |
---|---|
Type of entry: | Secondary publication |
Title: | A digital beam-phase control system for a heavy-ion synchrotron with a double-harmonic cavity system |
Language: | English |
Date: | 2022 |
Place of Publication: | Darmstadt |
Year of primary publication: | 2013 |
Publisher: | Joint Accelerator Conferences Website |
Book Title: | IPAC2013: Proceedings of the 4th International Particle Accelerator Conference |
Event Title: | IPAC2013: the 4th International Particle Accelerator Conference |
Event Location: | Shanghai, China |
Event Dates: | 12.05.2013-17.05.2013 |
DOI: | 10.26083/tuprints-00020328 |
Corresponding Links: | |
Origin: | Secondary publication service |
Abstract: | For the new Facility for Antiproton and Ion Research (FAIR) at GSI Helmholtzzentrum für Schwerionenforschung GmbH (http://www.gsi.de), the heavy ion synchrotron SIS18 will be operated with a double harmonic cavity system. The second cavity, running at twice the fundamental frequency, is used to create a lengthened bucket which introduces nonlinearities to the control system. To damp longitudinal rigid dipole oscillations a digital feedback system consisting of a filter and an integrator is used. For the existing single-harmonic setup an FIR-filter is implemented which realizes a multiple bandpass filter with the first passband centre frequency close to the synchrotron frequency. Both, the feedback gain and the passband frequency of the filter depend on the actual value of the synchrotron frequency. It was shown by simulations and in an experiment that this setup can be transferred to a double-harmonic cavity system obtaining similar results for the region of stabilizing feedback parameters, if the oscillation frequency of the bunch barycenter is considered instead of the synchrotron frequency of a linearized bucket. |
Status: | Publisher's Version |
URN: | urn:nbn:de:tuda-tuprints-203280 |
Classification DDC: | 600 Technology, medicine, applied sciences > 620 Engineering and machine engineering |