TU Darmstadt / ULB / TUprints

A primary radiation standard based on quantum nonlinear optics

Lemieux, Samuel ; Giese, Enno ; Fickler, Robert ; Chekhova, Maria V. ; Boyd, Robert W. (2024)
A primary radiation standard based on quantum nonlinear optics.
In: Nature Physics, 2019, 15 (6)
doi: 10.26083/tuprints-00027264
Article, Secondary publication, Postprint

[img] Text
A primary radiation standard.pdf
Copyright Information: In Copyright.

Download (1MB)
[img] Text
A primary radiation standard supplemntary.pdf
Copyright Information: In Copyright.

Download (1MB)
Item Type: Article
Type of entry: Secondary publication
Title: A primary radiation standard based on quantum nonlinear optics
Language: English
Date: 22 August 2024
Place of Publication: Darmstadt
Year of primary publication: 2019
Place of primary publication: Basingstoke
Publisher: Springer
Journal or Publication Title: Nature Physics
Volume of the journal: 15
Issue Number: 6
Collation: 6 Seiten
DOI: 10.26083/tuprints-00027264
Corresponding Links:
Origin: Secondary publication service
Abstract:

The black body remains the most prominent source of light for absolute radiometry. Its main alternative, synchrotron radiation, requires costly and large facilities. Quantum optics offers a new radiometric source: parametric down-conversion (PDC), a nonlinear optical process, in which pairwise photon correlations enable absolute calibration of photodetectors. Since the emission rate crucially depends on the brightness of the electromagnetic field, quantum-mechanical fluctuations of the vacuum7 can be seen as a seed of spontaneous PDC, and their amplitude is a natural radiometric standard. Thus, they allow for the calibration of the spectral radiance of light sources by measuring the ratio between seeded and unseeded PDC. Here, we directly use the frequency spectrum of the electromagnetic vacuum to trigger spontaneous PDC and employ the generated light to infer the spectral response of a spectrometer over a broad spectral range. Then, we deduce the absolute quantum efficiency from the spectral shape of PDC in the high-gain regime, without relying on a seed or reference detector. Our results compare well with the ones obtained with a reference lamp, demonstrating a promising primary radiation standard.