TU Darmstadt / ULB / TUprints

Entwicklung einer Sonde zur Online-Messung von Verdampferwandkorrosion

Zorbach, Ingo Sebastian (2013)
Entwicklung einer Sonde zur Online-Messung von Verdampferwandkorrosion.
Technische Universität Darmstadt
Ph.D. Thesis, Primary publication

[img]
Preview
Text
Dissertation Ingo Zorbach upload ULB 2013-05-28.pdf
Copyright Information: CC BY-NC-ND 2.5 Generic - Creative Commons, Attribution, NonCommercial, NoDerivs .

Download (6MB) | Preview
Item Type: Ph.D. Thesis
Type of entry: Primary publication
Title: Entwicklung einer Sonde zur Online-Messung von Verdampferwandkorrosion
Language: German
Referees: Epple, Prof. Bernd ; Oechsner, Prof. Matthias
Date: 2013
Place of Publication: Darmstadt
Date of oral examination: 5 February 2013
Abstract:

In kohlebefeuerten Kraftwerken tritt unter bestimmten Bedingungen am Verdampfer Korrosion auf. Im Rahmen dieser Arbeit wurde ein Messsystem entwickelt, das speziell auf die Randbedingungen am Verdampfer angepasst worden ist und das es ermöglicht, die Korrosionsrate des Verdampfer-werkstoffes online zu messen. Die Korrosionssonde besteht aus einer Trägerlanze mit drei gekühlten Sensorelektroden an der Spitze, die parallel zur Membranwand des Verdampfers eingebaut werden. Die Messung der Korrosionsrate erfolgt elektrochemisch. Das entwickelte System besteht aus vier unabhängigen Sonden, die mit einer zentralen Einheit zur Regelung der Sondentemperatur und zur Datenaufzeichnung verbunden sind. Erprobt wurde die Sonde sowohl in mit Steinkohle befeuerten Kraftwerken als auch in einem Braunkohlekraftwerk. Die gewonnen Ergebnisse stimmten dabei gut mit Betriebserfahrungen der Anlagen überein.

Alternative Abstract:
Alternative AbstractLanguage

Corrosion of evaporator tubing occurs typically in sub stoichiometric conditions in lignite or hard coal fired power plants. This work describes the development of an online measurement system for the corrosion of evaporator tubing and its testing in several power plants. The corrosion is detected by means of the measurement of electrochemical reactions on three sensor electrodes, placed on the front tip of a lance. The temperature controlled sensor electrodes are flat and installed parallel to the evaporator wall. The developed measurement system consists of four independently controlled sensor lances which are connected to a central unit for temperature control, data acquisition and remote access to the system. The system has been intensively tested in hard coal and lignite fired power plants. The measured data were in agreement with the experience of the power plant´s operators.

English
Uncontrolled Keywords: Korrosion, Verdampfer, Kohlekraftwerk, Braunkohle, unterstöchiometrisch, H2S, Online-Messung
Alternative keywords:
Alternative keywordsLanguage
online corrosion measurement, lignite, hard coal, coal, sub stoichiometric, H2S, evaporator, corrosion,UNSPECIFIED
URN: urn:nbn:de:tuda-tuprints-34206
Classification DDC: 600 Technology, medicine, applied sciences > 620 Engineering and machine engineering
Divisions: 16 Department of Mechanical Engineering > Institute for Energy and Power Plant Technology (EKT)
16 Department of Mechanical Engineering > Institut für Energiesysteme und Energietechnik (EST)
16 Department of Mechanical Engineering > Center for Engineering Materials, State Materials Testing Institute Darmstadt (MPA) Chair and Institute for Materials Technology (IfW)
Date Deposited: 21 Jun 2013 06:12
Last Modified: 09 Jul 2020 00:20
URI: https://tuprints.ulb.tu-darmstadt.de/id/eprint/3420