Al-Baradoni, Nassr ; Krech, Martin ; Groche, Peter (2024)
In-process calibration of smart structures produced by incremental forming.
In: Production Engineering : Research and Development, 2021, 15 (1)
doi: 10.26083/tuprints-00023951
Article, Secondary publication, Publisher's Version
Text
s11740-020-01002-6.pdf Copyright Information: CC BY 4.0 International - Creative Commons, Attribution. Download (4MB) |
Item Type: | Article |
---|---|
Type of entry: | Secondary publication |
Title: | In-process calibration of smart structures produced by incremental forming |
Language: | English |
Date: | 30 April 2024 |
Place of Publication: | Darmstadt |
Year of primary publication: | February 2021 |
Place of primary publication: | Berlin ; Heidelberg |
Publisher: | Springer |
Journal or Publication Title: | Production Engineering : Research and Development |
Volume of the journal: | 15 |
Issue Number: | 1 |
DOI: | 10.26083/tuprints-00023951 |
Corresponding Links: | |
Origin: | Secondary publication DeepGreen |
Abstract: | Smart load-bearing structures are created by forming integration of functional materials into passive metallic components with target-oriented pre-stress conditions by rotary swaging. Their sensory capability cannot only be used during the utilization but also during the manufacturing phase. Previous works demonstrated how this capability paves the way for efficient monitoring and controlling of the used integration process. In search of an even higher overall efficiency of the manufacturing chain, the subsequent costly calibration step deserves closer attention. Therefore, a cost- and time-efficient approach for the process-integrated calibration of a sensor-integrated structure is proposed in this paper. During the in-process calibration, the acting process forces are measured both in the integrated sensor and in a special-built clamping fixture. The measured data can be transferred into calibration slopes of the sensory structures. A suitable signal processing based on the process characteristics is performed to compensate interference effects on the raw signals. As a result, an accuracy of the calibration better than 2% of the nominal value compared to an offline standardized calibration is achieved with the in-line calibration method. Consequently, efficiency in the manufacturing of sensory structures is further boosted by avoidance of setup or logistical operations. |
Uncontrolled Keywords: | Smart structures, Calibration of smart structures, Incremental forming, Joining by forming |
Status: | Publisher's Version |
URN: | urn:nbn:de:tuda-tuprints-239519 |
Classification DDC: | 600 Technology, medicine, applied sciences > 620 Engineering and machine engineering 600 Technology, medicine, applied sciences > 670 Manufacturing |
Divisions: | 16 Department of Mechanical Engineering > Institute for Production Engineering and Forming Machines (PtU) |
Date Deposited: | 30 Apr 2024 09:25 |
Last Modified: | 30 Jul 2024 11:40 |
SWORD Depositor: | Deep Green |
URI: | https://tuprints.ulb.tu-darmstadt.de/id/eprint/23951 |
PPN: | 520219430 |
Export: |