Schwarz, Maximilian ; Behnisch, Justus ; Trippel, Jana ; Engelhart, Markus ; Wagner, Martin (2023)
Oxygen Transfer in Two-Stage Activated Sludge Wastewater Treatment Plants.
In: Water, 2021, 13 (14)
doi: 10.26083/tuprints-00019621
Article, Secondary publication, Publisher's Version
|
Text
water-13-01964.pdf Copyright Information: CC BY 4.0 International - Creative Commons, Attribution. Download (3MB) | Preview |
Item Type: | Article |
---|---|
Type of entry: | Secondary publication |
Title: | Oxygen Transfer in Two-Stage Activated Sludge Wastewater Treatment Plants |
Language: | English |
Date: | 14 November 2023 |
Place of Publication: | Darmstadt |
Year of primary publication: | 2021 |
Place of primary publication: | Basel |
Publisher: | MDPI |
Journal or Publication Title: | Water |
Volume of the journal: | 13 |
Issue Number: | 14 |
Collation: | 19 Seiten |
DOI: | 10.26083/tuprints-00019621 |
Corresponding Links: | |
Origin: | Secondary publication DeepGreen |
Abstract: | Aeration is an energy-intensive process of aerobic biological treatment in wastewater treatment plants (WWTP). Two-stage processes enable energy-efficient operation, but oxygen transfer has not been studied in depth before. In this study, α-factors were determined with long-term ex situ steady-state off-gas measurements in pilot-scale test reactors (5.8 m height, 8.3 m³) coupled to full-scale activated sludge basins. A two-stage WWTP with more than 1 Mio population equivalent was studied over 13 months including rain and dry weather conditions. Operating data, surfactant concentrations throughout the two-stage process, and the effect of reverse flexing on pressure loss of diffusers were examined. The values of αmean, αmin, and αmax for design load cases of aeration systems were determined as 0.45, 0.33, and 0.54 in the first high-rate carbon removal stage and as 0.80, 0.69, and 0.91 in the second nitrification stage, respectively. The first stage is characterized by a distinct diurnal variation and decrease in α-factor during stormwater treatment. Surfactants and the majority of the total organic carbon (TOC) load are effectively removed in the first stage; hence, α-factors in the second stage are higher and have a more consistent diurnal pattern. Proposed α-factors enable more accurate aeration system design of two-stage WWTPs. Fouling-induced diffuser pressure loss can be restored effectively with reverse flexing in both treatment stages. |
Uncontrolled Keywords: | aeration, alpha (α), fine-bubble diffusers, high-rate activated sludge systems (HRAS), off-gas, reverse flexing, surfactants, TOC F/M ratio, TOC sludge loading, wastewater treatment |
Status: | Publisher's Version |
URN: | urn:nbn:de:tuda-tuprints-196213 |
Additional Information: | This article belongs to the Section Wastewater Treatment and Reuse |
Classification DDC: | 600 Technology, medicine, applied sciences > 624 Civil engineering and environmental protection engineering |
Divisions: | 13 Department of Civil and Environmental Engineering Sciences > Institute IWAR |
Date Deposited: | 14 Nov 2023 14:03 |
Last Modified: | 17 Nov 2023 10:19 |
SWORD Depositor: | Deep Green |
URI: | https://tuprints.ulb.tu-darmstadt.de/id/eprint/19621 |
PPN: | 513263896 |
Export: |
View Item |