TU Darmstadt / ULB / TUprints

Digital image correlation strain measurement of ultra‐high‐performance concrete‐prisms under static and cyclic bending‐tensile stress

Harenberg, Stefan ; Pahn, Matthias ; Malárics‐Pfaff, Viktória ; Dehn, Frank ; Caggiano, Antonio ; Schicchi, Diego S. ; Yang, Sha ; Koenders, Eddie (2024)
Digital image correlation strain measurement of ultra‐high‐performance concrete‐prisms under static and cyclic bending‐tensile stress.
In: Structural Concrete, 2019, 20 (4)
doi: 10.26083/tuprints-00016721
Article, Secondary publication, Publisher's Version

[img] Text
SUCO_SUCO201900033.pdf
Copyright Information: CC BY 4.0 International - Creative Commons, Attribution.

Download (17MB)
Item Type: Article
Type of entry: Secondary publication
Title: Digital image correlation strain measurement of ultra‐high‐performance concrete‐prisms under static and cyclic bending‐tensile stress
Language: English
Date: 26 January 2024
Place of Publication: Darmstadt
Year of primary publication: 2019
Place of primary publication: Malden
Publisher: John Wiley & Sons
Journal or Publication Title: Structural Concrete
Volume of the journal: 20
Issue Number: 4
DOI: 10.26083/tuprints-00016721
Corresponding Links:
Origin: Secondary publication DeepGreen
Abstract:

This paper provides experimental results on investigations for the validation of photogrammetric strain measurements of ultra‐high‐performance concrete (UHPC)‐prisms subjected to static and cyclic bending‐tensile stress. For this purpose, 4 static and 5 cyclic test series were performed. Damage progresses during loading are monitored by means of a digital image correlation (DIC) system and a clip gauge. The control of the DIC by trigger lists and the measurement noise as a function of the measurement rate are examined. All static tests were performed force controlled with the same testing speed and the same measuring rate of DIC and clip gauge. All cyclic tests were performed with the same upper and lower stress levels but with different loading rates.

During the static tests, the DIC can be used to make accurate strain measurements before UHPC failure. In the cyclic tests, the measurement noise of the DIC decreases with an increasing measuring rate. The tests performed confirm the control of the DIC by trigger lists for cyclic tests on UHPC‐prisms and show that the measurement noise is negligible in static and cyclic tests.

Uncontrolled Keywords: cyclic bending tests, DIC, fatigue, photogrammetry, UHPC
Status: Publisher's Version
URN: urn:nbn:de:tuda-tuprints-167215
Additional Information:

Special Issue: Special theme "Fatigue"

Classification DDC: 600 Technology, medicine, applied sciences > 624 Civil engineering and environmental protection engineering
600 Technology, medicine, applied sciences > 690 Building and construction