Logo des Repositoriums
  • English
  • Deutsch
Anmelden
Keine TU-ID? Klicken Sie hier für mehr Informationen.
  1. Startseite
  2. Publikationen
  3. Publikationen der Technischen Universität Darmstadt
  4. Zweitveröffentlichungen
  5. Experience Report of Potential Free Temperature Measurement with commercially available Pyrometers in gas insulated systems
 
  • Details
2022
Zweitveröffentlichung
Konferenzveröffentlichung
Verlagsversion

Experience Report of Potential Free Temperature Measurement with commercially available Pyrometers in gas insulated systems

File(s)
Download
Hauptpublikation
2022.08.31 VDE Paper.pdf
CC BY-NC-ND 4.0 International
Format: Adobe PDF
Size: 1.23 MB
TUDa URI
tuda/9923
URN
urn:nbn:de:tuda-tuprints-231062
DOI
10.26083/tuprints-00023106
Autor:innen
Hallas, Martin ORCID 0000-0002-3372-2806
Moxter, Julian
Hinrichsen, Volker ORCID 0000-0002-8732-1426
Juhre, Karsten
Tenzer, Michael ORCID 0000-0002-4353-3654
Kurzbeschreibung (Abstract)

A potential free temperature measurement in gas insulated switchgear and lines (GIS/GIL) was investigated within an HVDC research project, because the temperature is of high importance during development and operation of HVDC equipment. Infrared spectrum measurement of the heated inner conductor by pyrometer sensors has emerged as the best technical solution for HVDC GIS/GIL. To optimize the infrared emission of the inner conductor, it was painted with black varnish. The sensor had to be adjusted to the infrared transmission of the pressurized insulating gas atmosphere. Experiences as well as methods to perform such a calibration are shown in the paper. A calibration by adjusting transmission and emission coefficients inside the sensor software did not succeeded, because the coefficients differed for variable sensor ambient temperatures. A successful calibration was possible by considering two major variables: the pyrometer output as well as the sensor ambient temperature. However, certain limits of the pyrometer measurement in GIS/GIL were observed as well. The EMC performance of the pyrometer was improved by an additional electronic unit, which protects the commercial electronics. Overall, the potential free temperature measurement could be performed during the long-term operation of the regarded HVDC GIL system. Typical temperature curves based on the calibrated pyrometer sensor are shown.

Freie Schlagworte

potential free temper...

pyrometer

gas-insulated system

Sprache
Englisch
Fachbereich/-gebiet
18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme > Hochspannungstechnik
DDC
600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften und Maschinenbau
Institution
Universitäts- und Landesbibliothek Darmstadt
Ort
Darmstadt
Veranstaltungstitel
VDE Hochspannungstechnik 2022
Veranstaltungsort
Berlin, Germany
Startdatum der Veranstaltung
08.11.2022
Enddatum der Veranstaltung
10.11.2022
Buchtitel
VDE Hochspannungstechnik : 8. – 10. November 2022 in Berlin
Titel der Reihe
ETG-Fachberichte
Bandnummer der Reihe
169
ISBN
978-3-8007-5978-1
ISSN
0341-3934
Verlag
VDE Verlag
Publikationsjahr der Erstveröffentlichung
2022
PPN
520232895
Zusätzliche Links (Organisation)
https://www.vde-hochspannungstechnik.de/de/2022

  • TUprints Leitlinien
  • Cookie-Einstellungen
  • Impressum
  • Datenschutzbestimmungen
  • Webseitenanalyse
Diese Webseite wird von der Universitäts- und Landesbibliothek Darmstadt (ULB) betrieben.