Logo des Repositoriums
  • English
  • Deutsch
Anmelden
Keine TU-ID? Klicken Sie hier für mehr Informationen.
  1. Startseite
  2. Publikationen
  3. Publikationen der Technischen Universität Darmstadt
  4. Zweitveröffentlichungen (aus DeepGreen)
  5. Time- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors
 
  • Details
2020
Zweitveröffentlichung
Artikel
Verlagsversion

Time- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors

File(s)
Download

mstabc63esupp1.pdf
CC BY 4.0 International
Format: Adobe PDF
Size: 4.3 MB
Download

mst_32_3_035903.pdf
CC BY 4.0 International
Format: Adobe PDF
Size: 2.87 MB
TUDa URI
tuda/8026
URN
urn:nbn:de:tuda-tuprints-204706
DOI
10.26083/tuprints-00020470
Autor:innen
Backis, A. ORCID 0000-0003-2471-9231
Khaplanov, A.
Al Jebali, R.
Ammer, R.
Apostolidis, I.
Birch, J.
Lai, C. C.
Deen, P. P.
Etxegarai, M.
Ruette, N. de
Freita Ramos, J.
Förster, D. F.
Haettner, E.
Hall-Wilton, R.
Hamilton, D.
Höglund, C.
Kadletz, P. M.
Kanaki, K.
Karnickis, E.
Kirstein, O.
Kolya, S.
Kraujalyte, Z.
Laloni, A.
Livingston, K.
Löhman, O. ORCID 0000-0002-1527-1319
Maulerova, V.
Mauritzon, N.
Müller, F.
Lopez Higuera, I.
Richter, T.
Robinson, L.
Roth, R. ORCID 0000-0003-4991-712X
Shetty, M.
Taylor, J.
Woracek, R.
Xiong, W.
Kurzbeschreibung (Abstract)

The boron-10 based multi-grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few µeV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of ∼ µs short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of µs wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.

Freie Schlagworte

neutron detectors

gaseous detectors

boron-10

multi-grid detector

helium-3

time resolution

Sprache
Englisch
Fachbereich/-gebiet
05 Fachbereich Physik > Institut für Physik Kondensierter Materie (IPKM)
DDC
500 Naturwissenschaften und Mathematik > 530 Physik
Institution
Universitäts- und Landesbibliothek Darmstadt
Ort
Darmstadt
Titel der Zeitschrift / Schriftenreihe
Measurement Science and Technology
Jahrgang der Zeitschrift
32
Heftnummer der Zeitschrift
3
ISSN
1361-6501
Verlag
IOP Publishing
Ort der Erstveröffentlichung
Bristol
Publikationsjahr der Erstveröffentlichung
2020
Verlags-DOI
10.1088/1361-6501/abc63e
PPN
519002202

  • TUprints Leitlinien
  • Cookie-Einstellungen
  • Impressum
  • Datenschutzbestimmungen
  • Webseitenanalyse
Diese Webseite wird von der Universitäts- und Landesbibliothek Darmstadt (ULB) betrieben.