  5. Some thoughts regarding prototype installation tests of gas-insulated HVDC systems
 
  • Details
2017
Zweitveröffentlichung
Konferenzveröffentlichung
Verlagsversion

Some thoughts regarding prototype installation tests of gas-insulated HVDC systems

File(s)
Download
Hauptpublikation
Paper D1-110_Prototype installation tests of DC GISystems.pdf
Urheberrechtlich geschützt
Format: Adobe PDF
Size: 555.77 KB
TUDa URI
tuda/6039
URN
urn:nbn:de:tuda-tuprints-132977
DOI
10.26083/tuprints-00013297
Autor:innen
Neumann, Claus
Hallas, Martin ORCID 0000-0002-3372-2806
Felk, Mahmoud
Tenzer, Michael
Riechert, Uwe
Kurzbeschreibung (Abstract)

Based on service experience, gas-insulated HVAC systems feature a high degree of reliability and excellent long-term performance. This applies for gas-insulated switchgear (GIS) as well as for gas- insulated lines (GIL). Users intending to employ gas -insulated HVDC systems expect the same reliability and long-term performance. This leads to the question of the necessity of long-term tests on gas-insulated HVDC systems in general and to the formulation of relevant test procedures if applicable. The test mainly closes the lack of experience with the new HVDC technology under real service conditions. The test will be called “prototype installation test” to express the idea that this test should be carried out for collecting more experience with this kind of DC technology. The main part consists of a long-term test at DC voltage under high load conditions followed by a test with superimposed LI and SI voltage waveforms. A test duration in correspondence with practical load cycles of 30 days is suggested. The test at high load requires a current injection of the rated current into the HV circuit. AC as well as DC current heating is discussed. The test procedure for superimposed voltage testing in general and the testing with superimposed oscillating voltage in particular is presented. The oscillating impulse voltage is especially required in case of long test assemblies like GIL. Based on these con siderations a prototype installation test procedure is recommended, which can prove the long-term capability of gas-insulated HVDC systems. This proposal is also under discussion in JWG D1/B3.57.

Freie Schlagworte

Gas-insulated HVDC Sy...

long-term test

testing procedure

superimposed voltage ...

current heating

Sprache
Englisch
Fachbereich/-gebiet
18 Fachbereich Elektrotechnik und Informationstechnik > Institut für Elektrische Energiesysteme > Hochspannungstechnik
DDC
600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften und Maschinenbau
Institution
Universitäts- und Landesbibliothek Darmstadt
Ort
Darmstadt
Veranstaltungstitel
Cigré Winnipeg 2017 International Colloquium & Exhibition
Veranstaltungsort
Winnipeg, Canada
Startdatum der Veranstaltung
30.09.2017
Enddatum der Veranstaltung
06.10.2017
Buchtitel
SC A3, B4 & D1 Colloquium - Winnipeg 2017
Verlag
CIGRE
Publikationsjahr der Erstveröffentlichung
2017
PPN
49051880X
Zusätzliche Infomationen
Study Committees: A3, B4 & D1
Zusätzliche Links (Verlag)
http://www.cigre.org/

  • TUprints Leitlinien
  • Cookie-Einstellungen
  • Impressum
  • Datenschutzbestimmungen
  • Webseitenanalyse
Diese Webseite wird von der Universitäts- und Landesbibliothek Darmstadt (ULB) betrieben.