Logo des Repositoriums
  • English
  • Deutsch
Anmelden
Keine TU-ID? Klicken Sie hier für mehr Informationen.
  1. Startseite
  2. Publikationen
  3. Publikationen der Technischen Universität Darmstadt
  4. Zweitveröffentlichungen (aus DeepGreen)
  5. Applicability and Limitations of a Capillary-LC Column-Switching System Using Hybrid Graphene-Based Stationary Phases
 
  • Details
2023
Zweitveröffentlichung
Artikel
Verlagsversion

Applicability and Limitations of a Capillary-LC Column-Switching System Using Hybrid Graphene-Based Stationary Phases

File(s)
Download
Hauptpublikation
molecules-28-04999.pdf
CC BY 4.0 International
Format: Adobe PDF
Size: 2.66 MB
TUDa URI
tuda/10771
URN
urn:nbn:de:tuda-tuprints-242536
DOI
10.26083/tuprints-00024253
Autor:innen
Basolli Borsatto, João Victor ORCID 0000-0002-1890-6076
Vasconcelos Soares Maciel, Edvaldo ORCID 0000-0002-1231-7190
Cifuentes, Alejandro ORCID 0000-0002-7464-0217
Lanças, Fernando Mauro
Kurzbeschreibung (Abstract)

Graphene oxide sheets fixed over silica particles (SiGO) and their modification functionalized with C18 and endcapped (SiGO-C18ec) have been reported as sorbents for extraction and analytical columns in LC. In this study, a SiGO column was selected as the extraction column and a SiGO-C18ec as the analytical column to study the applicability and limitations of a column-switching system composed exclusively of columns packed with graphene-based sorbents. Pyriproxyfen and abamectin B1a were selected as the analytes, and orange-flavored carbonated soft drinks as the matrix. The proposed system could be successfully applied to the pyriproxyfen analysis in a concentration range between 0.5 to 25 µg/mL presenting a linearity of R² = 0.9931 and an intra-day and inter-day accuracy of 82.2–111.4% (RSD < 13.3%) and 95.5–99.8% (RSD < 12.7%), respectively. Furthermore, the matrix composition affected the area observed for the pyriproxyfen: the higher the concentration of orange juice in the soft drink, the higher the pyriproxyfen the signal observed. Additionally, the SiGO extraction column presented a life use of 120 injections for this matrix. In contrast, the proposed system could not apply to the analysis of abamectin B1a, and the SiGO-C18ec analytical column presented significant tailing compared to a similar approach with a C18 analytical column.

Freie Schlagworte

capillary liquid chro...

graphene-based materi...

packed column

column switching

direct injection

SiGO

SiGO-C18ec

Sprache
Englisch
Fachbereich/-gebiet
07 Fachbereich Chemie > Clemens-Schöpf-Institut > Fachgebiet Biochemie
DDC
500 Naturwissenschaften und Mathematik > 540 Chemie
Institution
Universitäts- und Landesbibliothek Darmstadt
Ort
Darmstadt
Titel der Zeitschrift / Schriftenreihe
Molecules
Jahrgang der Zeitschrift
28
Heftnummer der Zeitschrift
13
ISSN
1420-3049
Verlag
MDPI
Publikationsjahr der Erstveröffentlichung
2023
Verlags-DOI
10.3390/molecules28134999
PPN
51216133X
Zusätzliche Infomationen
This article belongs to the Special Issue Food Analysis in the 21st Century: Challenges and Possibilities

  • TUprints Leitlinien
  • Cookie-Einstellungen
  • Impressum
  • Datenschutzbestimmungen
  • Webseitenanalyse
Diese Webseite wird von der Universitäts- und Landesbibliothek Darmstadt (ULB) betrieben.