TU Darmstadt / ULB / TUprints

Analysis of short-circuit transients in the LHC main dipole circuit

Liakopoulou, A. ; Annema, A. J. ; Bortot, L. ; Charifoulline, Z. ; Maciejewski, M. ; Prioli, M. ; Ravaioli, E. ; Salm, C. ; Schmitz, J. ; Verweij, A. P. (2024)
Analysis of short-circuit transients in the LHC main dipole circuit.
In: Journal of Physics: Conference Series, 2020, 1559
doi: 10.26083/tuprints-00021271
Article, Secondary publication, Publisher's Version

[img] Text
JPCS_1559_1_012077.pdf
Copyright Information: CC BY 3.0 Unported - Creative Commons, Attribution.

Download (1MB)
Item Type: Article
Type of entry: Secondary publication
Title: Analysis of short-circuit transients in the LHC main dipole circuit
Language: English
Date: 11 June 2024
Place of Publication: Darmstadt
Year of primary publication: 2020
Place of primary publication: Bristol
Publisher: IOP Publishing
Journal or Publication Title: Journal of Physics: Conference Series
Volume of the journal: 1559
Collation: 10 Seiten
DOI: 10.26083/tuprints-00021271
Corresponding Links:
Origin: Secondary publication DeepGreen
Abstract:

After the occurrence and detection of a short circuit to ground in the LHC main dipole circuit, a fast power abort is triggered and the current in the circuit starts decaying semi-exponentially from a maximum value of 11.85 kA to zero, with a time constant of 103 s. If a short to ground occurs, the current flows through the fuse that is present in the grounding subcircuit. Depending on the value of the thermal load, the fuse first enters a pre-arcing region where it starts intermittently blowing up, until the blow-up threshold is reached, after which it definitively blows up. A simulation scheme utilising a common interface between PSpice and Matlab is proposed in order to simulate the blow-up behaviour of the fuse and hence increase the accuracy of the circuit model for short circuits to ground. A parametric analysis of the short circuit to ground parameters is performed and a better understanding of the behaviour of the circuit under different conditions is obtained. The worst-case values of the voltage to ground in the LHC main dipole circuit are identified for both the case where the intermittent behaviour of the fuse is included in the model as well as for the case where the fuse is not modelled and a comparison between the two is given.

Identification Number: Artikel-ID: 012077
Status: Publisher's Version
URN: urn:nbn:de:tuda-tuprints-212713
Additional Information:

14th European Conference on Applied Superconductivity (EUCAS2019) 1-5 September 2019, Glasgow, UK

Classification DDC: 500 Science and mathematics > 530 Physics
600 Technology, medicine, applied sciences > 621.3 Electrical engineering, electronics
Divisions: 18 Department of Electrical Engineering and Information Technology > Institute for Accelerator Science and Electromagnetic Fields > Computational Electromagnetics
Date Deposited: 11 Jun 2024 09:23
Last Modified: 17 Jun 2024 08:48
SWORD Depositor: Deep Green
URI: https://tuprints.ulb.tu-darmstadt.de/id/eprint/21271
PPN: 519163141
Export:
Actions (login required)
View Item View Item